The Fundamentals of How Fire Behaves 

There are four recognised stages of fire behaviour: incipient, growth, fully developed and decay. 

Incipient (Ignition) 

This is the ignition phase, where heat, oxygen and fuel combine. You'll see small flames and minimal smoke at this point. It's also the stage where fire is easiest to control. 

Growth 

Once the incipient phase has run its course, the fire moves into the growth stage. Here it starts to spread to nearby materials. Temperature rises, smoke thickens and a layer of hot gas begins to form near the ceiling. 

Fully Developed 

This is the point of maximum intensity, where the fire consumes all available fuel in the surrounding area. It's marked by large flames, extreme heat that often exceeds 1,000°C, and thick black smoke. 

Decay 

In the final stage, the fuel supply or available oxygen has been used up. The fire begins to die down and transitions into smouldering. This stage is still dangerous, since heavy smoke and hot embers can remain for some time. 

The Fire Triangle 

Each of these stages can last a long time or be cut short, but how a fire spreads depends largely on what started it. The fire triangle refers to the elements that must be present for ignition to occur. 
Heat is the energy source needed to raise fuel to its ignition temperature and keep the fire burning. Water and foam are common extinguishing methods, since they cool the fire and absorb heat. 
 
Fuel is anything combustible that can burn, including wood, paper, fabric and flammable liquids or gases. Fires can be tackled at the fuel stage by removing the combustible material or allowing it to burn out. 
 
Oxygen acts as the oxidising agent that reacts with burning fuel. Normal air contains roughly 21% oxygen, and combustion generally needs an atmosphere with at least 16% oxygen present. Fire blankets and CO₂ extinguishers work by smothering the fire and cutting off its oxygen supply. 

Types of Fire Classification 

The types of fire are generally divided into six classifications, based on what caused them: 
Class A: Combustible materials 
Class B: Flammable liquids 
Class C: Flammable gases 
Class D: Burning metals 
Class E: Electrical fires 
Class F: Cooking oils and fats 
To comply with The Regulatory Reform (Fire Safety) Order 2005, building managers must supply fire safety equipment suited to the risks identified on their premises. A commercial kitchen, for example, needs a fire extinguisher rated for Class F fires. 
 
Some sites carry a higher risk of certain fire types than others. Different classes of fire also call for different fire stopping methods and extinguishers. This is why regular inspections matter so much. They help you identify which classes of fire your building is most exposed to, so you can put the right measures in place. 

Ways to Confine the Spread of Fires 

Once a fire starts, containing it is just as important as extinguishing it. A few key measures help limit how far fire, heat and smoke can travel through a building: 
Fire doors that hold back flames and smoke for a set period, giving people time to evacuate 
Fire stopping products such as intumescent seals and fire rated sealants, which close gaps around pipes, cables and ductwork 
Fire rated walls and floors that divide a building into separate zones 
Smoke control systems that clear smoke from escape routes and slow its spread between compartments 
These measures work best as part of a wider strategy rather than in isolation. A single weak point, such as an unsealed service penetration, can undermine the protection offered by everything around it. 

Protecting Your Building Against Fire Starts With Compartmentation 

Compartmentation is the practice of dividing a building into fire resistant sections. This ensures fire starting in one area is contained there for as long as possible. It relies on fire doors, fire rated walls and floors and properly sealed penetrations all working together as a single system. 
 
Over time, buildings change. Cables get added, pipework gets replaced and doors get propped open for convenience. Each of these small changes can quietly break down a building's compartmentation without anyone noticing until it's tested by a real fire. 
 
A compartmentation survey checks that these protective measures are still doing their job. It identifies gaps, damaged fire stopping and non-compliant doors. It also sets out what needs fixing to bring the building back in line with fire safety requirements. 
 
If you'd like to know more about how compartmentation could protect your building, our specialists at GRJ Surveying are on hand to talk through your options. 

Contact Our Team 

For more information about our services, please fill in the form below and a member of our team will be in touch. 
Share this post:
GRJ Surveying Logo
GRJ SURVEYING 
At GRJ Surveying, we provide that peace of mind and to maintain building compliance we can offer a service to attend site on a routine basis to survey passive fire protection to both fire walls and floors, completing any necessary firestopping works found following additional service installations or modifications. Our business operates nationwide in a variety of sectors including, education, commercial, health care, residential, MOD & MOJ. With expertise in fire protection through the installation of passive fire protection materials and systems, to create fire containment protecting life safety. 
IFC Certification
ISO 9001 Quality Management
SafeContractor Approved
CHAS Approved Contractor
Helpful Links 
Head Office: 
GRJ Contracting Ltd 
Cardigan House 
55 Burton Street 
Melton Mowbray 
LE13 1AW. 
TERMS OF USE | PRIVACY POLICY | Copyright © 2022 GRJ Contracting Ltd. All Rights Reserved. Branding by Carl Murch Design.